f5networks.f5_modules.bigip_gtm_monitor_firepass – Manages F5 BIG-IP GTM FirePass monitors

Note

This plugin is part of the f5networks.f5_modules collection (version 1.7.1).

To install it use: ansible-galaxy collection install f5networks.f5_modules.

To use it in a playbook, specify: f5networks.f5_modules.bigip_gtm_monitor_firepass.

New in version 1.0.0: of f5networks.f5_modules

Synopsis

  • Manages F5 BIG-IP GTM (now BIG-IP DNS) FirePass monitors.

Parameters

Parameter Choices/Defaults Comments
cipher_list
string
Specifies the list of ciphers for this monitor.
The items in the cipher list are separated with the colon : symbol.
When creating a new monitor, if this parameter is not specified, the default list is HIGH:!ADH.
concurrency_limit
integer
Specifies the maximum percentage of licensed connections currently in use under which the monitor marks the Secure Access Manager system up.
As an example, a setting of 95 percent means that the monitor marks the Secure Access Manager system up until 95 percent of licensed connections are in use.
When the number of in-use licensed connections exceeds 95 percent, the monitor marks the Secure Access Manager system down.
When creating a new monitor, if this parameter is not specified, the default is 95.
ignore_down_response
boolean
    Choices:
  • no
  • yes
Specifies the monitor allows more than one probe attempt per interval.
When yes, specifies the monitor ignores down responses for the duration of the monitor timeout. Once the monitor timeout is reached without the system receiving an up response, the system marks the object down.
When no, specifies the monitor immediately marks an object down when it receives a down response.
When creating a new monitor, if this parameter is not provided, the default value will be no.
interval
integer
The interval specifying how frequently the monitor instance of this template will run.
If this parameter is not provided when creating a new monitor, then the default value will be 30.
This value must be less than the timeout value.
ip
string
IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value will be '*'.
If this value is an IP address, a port number must be specified.
max_load_average
integer
Specifies the number the monitor uses to mark the Secure Access Manager system up or down.
The system compares the Max Load Average setting against a one-minute average of the Secure Access Manager system load.
When the Secure Access Manager system-load average falls within the specified Max Load Average, the monitor marks the Secure Access Manager system up.
When the average exceeds the setting, the monitor marks the system down.
When creating a new monitor, if this parameter is not specified, the default is 12.
name
string / required
Monitor name.
parent
string
Default:
"/Common/firepass_gtm"
The parent template of this monitor template. Once this value has been set, it cannot be changed. By default, this value is the tcp parent on the Common partition.
partition
string
Default:
"Common"
Device partition to manage resources on.
port
string
Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value will be '*'. Note that if specifying an IP address, a value between 1 and 65535 must be specified.
probe_timeout
integer
Specifies the number of seconds after which the system times out the probe request to the system.
When creating a new monitor, if this parameter is not provided, the default value will be 5.
provider
dictionary
added in 1.0.0 of f5networks.f5_modules
A dict object containing connection details.
auth_provider
string
Configures the auth provider for to obtain authentication tokens from the remote device.
This option is really used when working with BIG-IQ devices.
no_f5_teem
boolean
    Choices:
  • no
  • yes
If yes, TEEM telemetry data is not sent to F5.
You may omit this option by setting the environment variable F5_TEEM.
password
string / required
The password for the user account used to connect to the BIG-IP.
You may omit this option by setting the environment variable F5_PASSWORD.

aliases: pass, pwd
server
string / required
The BIG-IP host.
You may omit this option by setting the environment variable F5_SERVER.
server_port
integer
Default:
443
The BIG-IP server port.
You may omit this option by setting the environment variable F5_SERVER_PORT.
timeout
integer
Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error.
transport
string
    Choices:
  • rest ←
Configures the transport connection to use when connecting to the remote device.
user
string / required
The username to connect to the BIG-IP with. This user must have administrative privileges on the device.
You may omit this option by setting the environment variable F5_USER.
validate_certs
boolean
    Choices:
  • no
  • yes ←
If no, SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.
You may omit this option by setting the environment variable F5_VALIDATE_CERTS.
state
string
    Choices:
  • present ←
  • absent
When present, ensures the monitor exists.
When absent, ensures the monitor is removed.
target_password
string
Specifies the password, if the monitored target requires authentication.
target_username
string
Specifies the user name, if the monitored target requires authentication.
timeout
integer
The number of seconds in which the node or service must respond to the monitor request. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. You can change this to any number, however, it should be 3 times the interval number of seconds plus 1 second.
If this parameter is not provided when creating a new monitor, the default value will be 90.
update_password
string
    Choices:
  • always ←
  • on_create
always will update passwords if the target_password is specified.
on_create will only set the password for newly created monitors.

Notes

Note

  • For more information on using Ansible to manage F5 Networks devices see https://www.ansible.com/integrations/networks/f5.

  • Requires BIG-IP software version >= 12.

  • The F5 modules only manipulate the running configuration of the F5 product. To ensure that BIG-IP specific configuration persists to disk, be sure to include at least one task that uses the f5networks.f5_modules.bigip_config module to save the running configuration. Refer to the module’s documentation for the correct usage of the module to save your running configuration.

Examples

- name: Create a GTM FirePass monitor
  bigip_gtm_monitor_firepass:
    name: my_monitor
    ip: 1.1.1.1
    port: 80
    state: present
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

- name: Remove FirePass Monitor
  bigip_gtm_monitor_firepass:
    name: my_monitor
    state: absent
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

- name: Add FirePass monitor for all addresses, port 514
  bigip_gtm_monitor_firepass:
    name: my_monitor
    port: 514
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key Returned Description
cipher_list
string
changed
The new value for the cipher list.

Sample:
+3DES:+kEDH
concurrency_limit
integer
changed
The new value for the concurrency limit.

Sample:
95
ignore_down_response
boolean
changed
Whether to ignore the down response or not.

Sample:
True
interval
integer
changed
The new interval in which to run the monitor check.

Sample:
2
ip
string
changed
The new IP of IP/port definition.

Sample:
10.12.13.14
max_load_average
integer
changed
The new value for the max load average.

Sample:
12
parent
string
changed
New parent template of the monitor.

Sample:
firepass_gtm
port
string
changed
The new port the monitor checks the resource on.

Sample:
8080
probe_timeout
integer
changed
The new timeout in which the system will timeout the monitor probe.

Sample:
10
timeout
integer
changed
The new timeout in which the remote system must respond to the monitor.

Sample:
10


Authors

  • Tim Rupp (@caphrim007)

  • Wojciech Wypior (@wojtek0806)