ipmi_power – Power management for machine¶
New in version 2.2.
Requirements¶
The below requirements are needed on the host that executes this module.
- python >= 2.6
- pyghmi
Parameters¶
Parameter | Choices/Defaults | Comments |
---|---|---|
name
-
/ required
|
Hostname or ip address of the BMC.
|
|
password
-
/ required
|
Password to connect to the BMC.
|
|
port
-
|
Default: 623
|
Remote RMCP port.
|
state
-
/ required
|
|
Whether to ensure that the machine in desired state.
|
timeout
-
|
Default: 300
|
Maximum number of seconds before interrupt request.
|
user
-
/ required
|
Username to use to connect to the BMC.
|
Examples¶
# Ensure machine is powered on.
- ipmi_power:
name: test.testdomain.com
user: admin
password: password
state: on
Return Values¶
Common return values are documented here, the following are the fields unique to this module:
Key | Returned | Description |
---|---|---|
powerstate
string
|
success |
The current power state of the machine.
Sample:
True
|
Status¶
- This module is not guaranteed to have a backwards compatible interface. [preview]
- This module is maintained by the Ansible Community. [community]
Authors¶
- Bulat Gaifullin (gaifullinbf@gmail.com)
Hint