ce_info_center_log – Manages information center log configuration on HUAWEI CloudEngine switches¶
New in version 2.4.
Synopsis¶
Setting the Timestamp Format of Logs. Configuring the Device to Output Logs to the Log Buffer.
Parameters¶
Notes¶
Note
This module requires the netconf system service be enabled on the remote device being managed.
Recommended connection is
netconf
.This module also works with
local
connections for legacy playbooks.
Examples¶
- name: CloudEngine info center log test
hosts: cloudengine
connection: local
gather_facts: no
vars:
cli:
host: "{{ inventory_hostname }}"
port: "{{ ansible_ssh_port }}"
username: "{{ username }}"
password: "{{ password }}"
transport: cli
tasks:
- name: "Setting the timestamp format of logs"
ce_info_center_log:
log_time_stamp: date_tenthsecond
provider: "{{ cli }}"
- name: "Enabled to output information to the log buffer"
ce_info_center_log:
log_buff_enable: true
provider: "{{ cli }}"
- name: "Set the maximum number of logs in the log buffer"
ce_info_center_log:
log_buff_size: 100
provider: "{{ cli }}"
- name: "Set a rule for outputting logs to a channel"
ce_info_center_log:
module_name: aaa
channel_id: 1
log_enable: true
log_level: critical
provider: "{{ cli }}"
Return Values¶
Common return values are documented here, the following are the fields unique to this module:
Status¶
This module is not guaranteed to have a backwards compatible interface. [preview]
This module is maintained by the Ansible Community. [community]
Authors¶
QijunPan (@QijunPan)
Hint