Parameter |
Choices/Defaults |
Comments |
expiration_warning
integer
|
|
Specifies the number of days before a password expires.
This value determines when the BIG-IP system automatically warns users their password is about to expire.
|
max_duration
integer
|
|
Specifies the maximum number of days a password is valid.
|
max_login_failures
integer
|
|
Specifies the number of consecutive unsuccessful login attempts the system allows before locking out the user.
Specify zero (0) to disable this parameter.
|
min_duration
integer
|
|
Specifies the minimum number of days a password is valid.
|
min_length
integer
|
|
Specifies the minimum number of characters in a valid password.
This value must be between 6 and 255.
|
password_memory
integer
|
|
Specifies whether the user has configured the BIG-IP system to remember a password on a specific computer and how many passwords to remember.
|
policy_enforcement
boolean
|
|
Enables or disables the password policy on the BIG-IP system.
|
provider
dictionary
added in 1.0.0 of f5networks.f5_modules
|
|
A dict object containing connection details.
|
|
auth_provider
string
|
|
Configures the auth provider for to obtain authentication tokens from the remote device.
This option is really used when working with BIG-IQ devices.
|
|
no_f5_teem
boolean
|
|
If yes , TEEM telemetry data is not sent to F5.
You may omit this option by setting the environment variable F5_TEEM .
|
|
password
string
/ required
|
|
The password for the user account used to connect to the BIG-IP.
You may omit this option by setting the environment variable F5_PASSWORD .
aliases: pass, pwd
|
|
server
string
/ required
|
|
The BIG-IP host.
You may omit this option by setting the environment variable F5_SERVER .
|
|
server_port
integer
|
Default:
443
|
The BIG-IP server port.
You may omit this option by setting the environment variable F5_SERVER_PORT .
|
|
timeout
integer
|
|
Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error.
|
|
transport
string
|
|
Configures the transport connection to use when connecting to the remote device.
|
|
user
string
/ required
|
|
The username to connect to the BIG-IP with. This user must have administrative privileges on the device.
You may omit this option by setting the environment variable F5_USER .
|
|
validate_certs
boolean
|
|
If no , SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.
You may omit this option by setting the environment variable F5_VALIDATE_CERTS .
|
required_lowercase
integer
|
|
Specifies the number of lowercase alpha characters that must be present in a password for the password to be valid.
|
required_numeric
integer
|
|
Specifies the number of numeric characters that must be present in a password for the password to be valid.
|
required_special
integer
|
|
Specifies the number of special characters that must be present in a password for the password to be valid.
|
required_uppercase
integer
|
|
Specifies the number of uppercase alpha characters that must be present in a password for the password to be valid.
|