dellemc.openmanage.ome_firmware_baseline_info – Retrieves baseline details from OpenManage Enterprise
Note
This plugin is part of the dellemc.openmanage collection (version 3.6.0).
You might already have this collection installed if you are using the ansible
package.
It is not included in ansible-core
.
To check whether it is installed, run ansible-galaxy collection list
.
To install it, use: ansible-galaxy collection install dellemc.openmanage
.
To use it in a playbook, specify: dellemc.openmanage.ome_firmware_baseline_info
.
New in version 2.0.0: of dellemc.openmanage
Requirements
The below requirements are needed on the host that executes this module.
python >= 2.7.5
Parameters
Parameter |
Comments |
---|---|
Name of the baseline.If baseline_name is not provided, all the available firmware baselines are returned. |
|
OpenManage Enterprise or OpenManage Enterprise Modular IP address or hostname. |
|
OpenManage Enterprise or OpenManage Enterprise Modular password. |
|
OpenManage Enterprise or OpenManage Enterprise Modular HTTPS port. Default: 443 |
|
OpenManage Enterprise or OpenManage Enterprise Modular username. |
Notes
Note
Run this module from a system that has direct access to DellEMC OpenManage Enterprise.
This module supports
check_mode
.
Examples
---
- name: Retrieve details of all the available firmware baselines
dellemc.openmanage.ome_firmware_baseline_info:
hostname: "192.168.0.1"
username: "username"
password: "password"
- name: Retrieve details of a specific firmware baseline identified by its baseline name
dellemc.openmanage.ome_firmware_baseline_info:
hostname: "192.168.0.1"
username: "username"
password: "password"
baseline_name: "baseline_name"
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key |
Description |
---|---|
Details of the baselines. Returned: success Sample: {“@odata.id”: “/api/UpdateService/Baselines(239)”, “@odata.type”: “#UpdateService.Baselines”, “CatalogId”: 22, “ComplianceSummary”: {“ComplianceStatus”: “CRITICAL”, “NumberOfCritical”: 1, “NumberOfDowngrade”: 0, “NumberOfNormal”: 0, “NumberOfWarning”: 0}, “Description”: “baseline_description”, “DeviceComplianceReports@odata.navigationLink”: “/api/UpdateService/Baselines(239)/DeviceComplianceReports”, “DowngradeEnabled”: true, “Id”: 239, “Is64Bit”: true, “LastRun”: “2020-05-22 16:42:40.307”, “Name”: “baseline_name”, “RepositoryId”: 12, “RepositoryName”: “HTTP DELL”, “RepositoryType”: “DELL_ONLINE”, “Targets”: [{“Id”: 10342, “Type”: {“Id”: 1000, “Name”: “DEVICE”}}], “TaskId”: 41415, “TaskStatusId”: 2060} |
|
Overall baseline information. Returned: on error Sample: “Successfully fetched firmware baseline information.” |
Authors
Sajna Shetty(@Sajna-Shetty)