dellemc.openmanage.dellemc_configure_idrac_eventing module – Configures the iDRAC eventing related attributes
Note
This module is part of the dellemc.openmanage collection (version 5.5.0).
You might already have this collection installed if you are using the ansible
package.
It is not included in ansible-core
.
To check whether it is installed, run ansible-galaxy collection list
.
To install it, use: ansible-galaxy collection install dellemc.openmanage
.
You need further requirements to be able to use this module,
see Requirements for details.
To use it in a playbook, specify: dellemc.openmanage.dellemc_configure_idrac_eventing
.
New in dellemc.openmanage 1.0.0
Synopsis
This module allows to configure the iDRAC eventing related attributes.
Requirements
The below requirements are needed on the host that executes this module.
omsdk >= 1.2.488
python >= 3.8.6
Parameters
Parameter |
Comments |
---|---|
Email address for SNMP Trap. |
|
Alert number for Email configuration. |
|
Simple Mail Transfer Protocol Authentication. Choices:
|
|
The Privacy Enhanced Mail (PEM) file that contains a CA certificate to be used for the validation. |
|
Custom message for SNMP Trap reference. |
|
Destination for SNMP Trap. |
|
Destination number for SNMP Trap. |
|
Whether to Enable or Disable Email alert. Choices:
|
|
Whether to Enable or Disable iDRAC alerts. Choices:
|
|
iDRAC IP Address. |
|
iDRAC user password. |
|
iDRAC port. Default: |
|
iDRAC username. |
|
Password for SMTP authentication. |
|
Local mount path of the network share with read-write permission for ansible user. This option is mandatory for Network Share. |
|
Network share or a local path. |
|
Network share user password. This option is mandatory for CIFS Network Share. |
|
Network share user in the format ‘user@domain’ or ‘domain\user’ if user is part of a domain else ‘user’. This option is mandatory for CIFS Network Share. |
|
SMTP IP address for communication. |
|
SMTP Port number for access. |
|
Whether to Enable or Disable SNMP alert. Choices:
|
|
SNMP v3 username for SNMP Trap. |
|
The socket level timeout in seconds. Default: |
|
Username for SMTP authentication. |
|
If Configure Prior to collection version Choices:
|
Notes
Note
This module requires ‘Administrator’ privilege for idrac_user.
Run this module from a system that has direct access to Dell EMC iDRAC.
This module supports
check_mode
.
Examples
---
- name: Configure the iDRAC eventing attributes
dellemc.openmanage.dellemc_configure_idrac_eventing:
idrac_ip: "192.168.0.1"
idrac_user: "user_name"
idrac_password: "user_password"
ca_path: "/path/to/ca_cert.pem"
share_name: "192.168.0.1:/share"
share_password: "share_user"
share_user: "share_password"
share_mnt: "/mnt/share"
destination_number: "2"
destination: "1.1.1.1"
snmp_v3_username: "None"
snmp_trap_state: "Enabled"
email_alert_state: "Disabled"
alert_number: "1"
address: "[email protected]"
custom_message: "Custom Message"
enable_alerts: "Disabled"
authentication: "Enabled"
smtp_ip_address: "192.168.0.1"
smtp_port: "25"
username: "username"
password: "password"
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key |
Description |
---|---|
Details of the HTTP Error. Returned: on HTTP error Sample: |
|
Configures the iDRAC eventing attributes. Returned: success Sample: |
|
Successfully configured the iDRAC eventing settings. Returned: always Sample: |
Authors
Felix Stephen (@felixs88)