f5networks.f5_modules.bigip_gtm_monitor_firepass module – Manages F5 BIG-IP GTM FirePass monitors

Note

This module is part of the f5networks.f5_modules collection (version 1.25.0).

You might already have this collection installed if you are using the ansible package. It is not included in ansible-core. To check whether it is installed, run ansible-galaxy collection list.

To install it, use: ansible-galaxy collection install f5networks.f5\_modules.

To use it in a playbook, specify: f5networks.f5_modules.bigip_gtm_monitor_firepass.

New in f5networks.f5_modules 1.0.0

Synopsis

  • Manages F5 BIG-IP GTM (now BIG-IP DNS) FirePass monitors.

Parameters

Parameter

Comments

cipher_list

string

Specifies the list of ciphers for this monitor.

The items in the cipher list are separated with the colon : symbol.

When creating a new monitor, if this parameter is not specified, the default list is HIGH:!ADH.

concurrency_limit

integer

Specifies the maximum percentage of licensed connections currently in use under which the monitor marks the Secure Access Manager system up.

As an example, a setting of 95 percent means that the monitor marks the Secure Access Manager system up until 95 percent of licensed connections are in use.

When the number of in-use licensed connections exceeds 95 percent, the monitor marks the Secure Access Manager system down.

When creating a new monitor, if this parameter is not specified, the default is 95.

ignore_down_response

boolean

Specifies the monitor allows more than one probe attempt per interval.

When true, specifies the monitor ignores down responses for the duration of the monitor timeout. Once the monitor timeout is reached without the system receiving an up response, the system marks the object down.

When no, specifies the monitor immediately marks an object down when it receives a down response.

When creating a new monitor, if this parameter is not provided, the default value is false.

Choices:

  • false

  • true

interval

integer

The interval specifying how frequently the monitor instance of this template runs.

If this parameter is not provided when creating a new monitor, then the default value is 30.

This value must be less than the timeout value.

ip

string

IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value is ‘*’.

If this value is an IP address, a port number must be specified.

max_load_average

integer

Specifies the number the monitor uses to mark the Secure Access Manager system up or down.

The system compares the Max Load Average setting against a one-minute average of the Secure Access Manager system load.

When the Secure Access Manager system-load average falls within the specified Max Load Average, the monitor marks the Secure Access Manager system up.

When the average exceeds the setting, the monitor marks the system down.

When creating a new monitor, if this parameter is not specified, the default is 12.

name

string / required

Monitor name.

parent

string

The parent template of this monitor template. Once this value has been set, it cannot be changed. By default, this value is the tcp parent on the Common partition.

Default: "/Common/firepass_gtm"

partition

string

Device partition to manage resources on.

Default: "Common"

port

string

Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value is ‘*’. Note that if specifying an IP address, a value between 1 and 65535 must be specified.

probe_timeout

integer

Specifies the number of seconds after which the system times out the probe request to the system.

When creating a new monitor, if this parameter is not provided, the default value is 5.

provider

dictionary

added in f5networks.f5_modules 1.0.0

A dict object containing connection details.

auth_provider

string

Configures the auth provider for to obtain authentication tokens from the remote device.

This option is really used when working with BIG-IQ devices.

no_f5_teem

boolean

If yes, TEEM telemetry data is not sent to F5.

You may omit this option by setting the environment variable F5_TELEMETRY_OFF.

Previously used variable F5_TEEM is deprecated as its name was confusing.

Choices:

  • false ← (default)

  • true

password

aliases: pass, pwd

string / required

The password for the user account used to connect to the BIG-IP.

You may omit this option by setting the environment variable F5_PASSWORD.

server

string / required

The BIG-IP host.

You may omit this option by setting the environment variable F5_SERVER.

server_port

integer

The BIG-IP server port.

You may omit this option by setting the environment variable F5_SERVER_PORT.

Default: 443

timeout

integer

Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error.

transport

string

Configures the transport connection to use when connecting to the remote device.

Choices:

  • "rest" ← (default)

user

string / required

The username to connect to the BIG-IP with. This user must have administrative privileges on the device.

You may omit this option by setting the environment variable F5_USER.

validate_certs

boolean

If no, SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.

You may omit this option by setting the environment variable F5_VALIDATE_CERTS.

Choices:

  • false

  • true ← (default)

state

string

When present, ensures the monitor exists.

When absent, ensures the monitor is removed.

Choices:

  • "present" ← (default)

  • "absent"

target_password

string

Specifies the password, if the monitored target requires authentication.

target_username

string

Specifies the user name, if the monitored target requires authentication.

timeout

integer

The number of seconds in which the node or service must respond to the monitor request. If the target responds within the set time period, it is considered up. If the target does not respond within the set time period, it is considered down. You can change this to any number, however, it should be 3 times the interval number of seconds plus 1 second.

If this parameter is not provided when creating a new monitor, the default value is 90.

update_password

string

always updates passwords if the target_password is specified.

on_create only sets the password for newly created monitors.

Choices:

  • "always" ← (default)

  • "on_create"

Notes

Note

  • For more information on using Ansible to manage F5 Networks devices see https://www.ansible.com/integrations/networks/f5.

  • Requires BIG-IP software version >= 12.

  • The F5 modules only manipulate the running configuration of the F5 product. To ensure that BIG-IP specific configuration persists to disk, be sure to include at least one task that uses the f5networks.f5_modules.bigip_config module to save the running configuration. Refer to the module’s documentation for the correct usage of the module to save your running configuration.

Examples

- name: Create a GTM FirePass monitor
  bigip_gtm_monitor_firepass:
    name: my_monitor
    ip: 1.1.1.1
    port: 80
    state: present
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

- name: Remove FirePass Monitor
  bigip_gtm_monitor_firepass:
    name: my_monitor
    state: absent
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

- name: Add FirePass monitor for all addresses, port 514
  bigip_gtm_monitor_firepass:
    name: my_monitor
    port: 514
    provider:
      user: admin
      password: secret
      server: lb.mydomain.com
  delegate_to: localhost

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key

Description

cipher_list

string

The new value for the cipher list.

Returned: changed

Sample: "+3DES:+kEDH"

concurrency_limit

integer

The new value for the concurrency limit.

Returned: changed

Sample: 95

ignore_down_response

boolean

Whether to ignore the down response or not.

Returned: changed

Sample: true

interval

integer

The new interval in which to run the monitor check.

Returned: changed

Sample: 2

ip

string

The new IP of IP/port definition.

Returned: changed

Sample: "10.12.13.14"

max_load_average

integer

The new value for the max load average.

Returned: changed

Sample: 12

parent

string

New parent template of the monitor.

Returned: changed

Sample: "firepass_gtm"

port

string

The new port the monitor checks the resource on.

Returned: changed

Sample: "8080"

probe_timeout

integer

The new timeout in which the system will timeout the monitor probe.

Returned: changed

Sample: 10

timeout

integer

The new timeout in which the remote system must respond to the monitor.

Returned: changed

Sample: 10

Authors

  • Tim Rupp (@caphrim007)

  • Wojciech Wypior (@wojtek0806)