cisco.ucs.ucs_san_connectivity module – Configures SAN Connectivity Policies on Cisco UCS Manager
Note
This module is part of the cisco.ucs collection (version 1.10.0).
You might already have this collection installed if you are using the ansible
package.
It is not included in ansible-core
.
To check whether it is installed, run ansible-galaxy collection list
.
To install it, use: ansible-galaxy collection install cisco.ucs
.
You need further requirements to be able to use this module,
see Requirements for details.
To use it in a playbook, specify: cisco.ucs.ucs_san_connectivity
.
New in cisco.ucs 2.5
Synopsis
Configures SAN Connectivity Policies on Cisco UCS Manager.
Requirements
The below requirements are needed on the host that executes this module.
ucsmsdk
Parameters
Parameter |
Comments |
---|---|
A description of the policy. Cisco recommends including information about where and when to use the policy. Enter up to 256 characters. You can use any characters or spaces except the following: ` (accent mark), (backslash), ^ (carat), ” (double quote), = (equal sign), > (greater than), < (less than), or ‘ (single quote). |
|
IP address or hostname of Cisco UCS Manager. Modules can be used with the UCS Platform Emulator https://cs.co/ucspe |
|
The name of the SAN Connectivity Policy. This name can be between 1 and 16 alphanumeric characters. You cannot use spaces or any special characters other than - (hyphen), “_” (underscore), : (colon), and . (period). You cannot change this name after the policy is created. |
|
Org dn (distinguished name) Default: |
|
Password for Cisco UCS Manager authentication. |
|
Port number to be used during connection (by default uses 443 for https and 80 for http connection). |
|
If use_proxy is no, specfies proxy to be used for connection. e.g. ‘http://proxy.xy.z:8080’ |
|
If If Choices:
|
|
If Choices:
|
|
If Choices:
|
|
Username for Cisco UCS Manager authentication. Default: |
|
List of vHBAs used by the SAN Connectivity Policy. vHBAs used by the SAN Connectivity Policy must be created from a vHBA template. Each list element has the following suboptions: = name
= vhba_template
|
|
Name of the WWNN pool to use for WWNN assignment. Default: |
Examples
- name: Configure SAN Connectivity Policy
cisco.ucs.ucs_san_connectivity:
hostname: 172.16.143.150
username: admin
password: password
name: Cntr-FC-Boot
wwnn_pool: WWNN-Pool
vhba_list:
- name: Fabric-A
vhba_template: vHBA-Template-A
adapter_policy: Linux
- name: Fabric-B
vhba_template: vHBA-Template-B
adapter_policy: Linux
- name: Remove SAN Connectivity Policy
cisco.ucs.ucs_san_connectivity:
hostname: 172.16.143.150
username: admin
password: password
name: Cntr-FC-Boot
state: absent