dellemc.openmanage.idrac_redfish_storage_controller module – Configures the physical disk, virtual disk, and storage controller settings
Note
This module is part of the dellemc.openmanage collection (version 7.6.1).
You might already have this collection installed if you are using the ansible
package.
It is not included in ansible-core
.
To check whether it is installed, run ansible-galaxy collection list
.
To install it, use: ansible-galaxy collection install dellemc.openmanage
.
You need further requirements to be able to use this module,
see Requirements for details.
To use it in a playbook, specify: dellemc.openmanage.idrac_redfish_storage_controller
.
New in dellemc.openmanage 2.1.0
Synopsis
This module allows the users to configure the settings of the physical disk, virtual disk, and storage controller.
Requirements
The below requirements are needed on the host that executes this module.
python >= 3.9.6
Parameters
Parameter |
Comments |
---|---|
Apply time of the attributes. This is applicable only to attributes.
Choices:
|
|
Dictionary of controller attributes and value pair. This feature is only supported for iDRAC9 with firmware version 6.00.00.00 and above controller_id is required for this operation. apply_time and maintenance_window is applicable for attributes. attributes is mutually exclusive with command. Use https://I(idrac_ip/redfish/v1/Schemas/DellOemStorageController.json) to view the attributes. |
|
IP address of the target out-of-band controller. For example- <ipaddress>:<port>. |
|
The Privacy Enhanced Mail (PEM) file that contains a CA certificate to be used for the validation. |
|
These actions may require a system reset, depending on the capabilities of the controller.
Choices:
|
|
Fully Qualified Device Descriptor (FQDD) of the storage controller. For example-‘RAID.Slot.1-1’. This option is mandatory when command is This option is mandatory for attributes. |
|
Provides the option if the module has to wait for the job to be completed. This is applicable for attributes when apply_time is Choices:
|
|
The maximum wait time of job completion in seconds before the job tracking is stopped. This option is applicable when job_wait is Default: |
|
A new security key passphrase that the encryption-capable controller uses to create the encryption key. The controller uses the encryption key to lock or unlock access to the Self-Encrypting Drive (SED). Only one encryption key can be created for each controller. This is mandatory when command is The length of the key can be a maximum of 32 characters in length, where the expanded form of the special character is counted as a single character. The key must contain at least one character from each of the character classes: uppercase, lowercase, number, and special character. |
|
This is a user supplied text label associated with the passphrase. This is mandatory when command is The length of key_id can be a maximum of 32 characters in length and should not have any spaces. |
|
Option to schedule the maintenance window. This is required when apply_time is |
|
The duration in seconds for the maintenance window. Default: |
|
The start time for the maintenance window to be scheduled. The format is YYYY-MM-DDThh:mm:ss<offset> <offset> is the time offset from UTC that the current timezone set in iDRAC in the format: +05:30 for IST. |
|
Encryption mode of the encryption capable controller. This option is applicable only when command is
Choices:
|
|
Security key passphrase used by the encryption-capable controller. This option is mandatory when command is |
|
Password of the target out-of-band controller. |
|
Capacity of the virtual disk to be expanded in MB. Check mode and Idempotency is not supported for size. Minimum Online Capacity Expansion size must be greater than 100 MB of the current size. When command is |
|
Fully Qualified Device Descriptor (FQDD) of the target physical drive. This is mandatory when command is If volume_id is not specified or empty, this physical drive will be assigned as a global hot spare when command is When command is Notes: Global or Dedicated hot spare can be assigned only once for a physical disk, Re-assign cannot be done when command is |
|
The socket level timeout in seconds. Default: |
|
Username of the target out-of-band controller. |
|
If Configure Prior to collection version Choices:
|
|
Fully Qualified Device Descriptor (FQDD) of the volume. Applicable if command is volume_id or target is required when the command is To know the number of volumes to which a hot spare can be assigned, refer iDRAC Redfish API documentation. |
Notes
Note
Run this module from a system that has direct access to Dell iDRAC.
This module is supported on iDRAC9.
This module always reports as changes found when command is
ReKey
,BlinkTarget
, andUnBlinkTarget
.This module supports
check_mode
.
Examples
---
- name: Assign dedicated hot spare
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
volume_id:
- "Disk.Virtual.0:RAID.Slot.1-1"
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- assign_dedicated_hot_spare
- name: Assign global hot spare
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- assign_global_hot_spare
- name: Unassign hot spare
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
command: UnassignSpare
tags:
- un-assign-hot-spare
- name: Set controller encryption key
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "SetControllerKey"
controller_id: "RAID.Slot.1-1"
key: "PassPhrase@123"
key_id: "mykeyid123"
tags:
- set_controller_key
- name: Rekey in LKM mode
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "ReKey"
controller_id: "RAID.Slot.1-1"
key: "NewPassPhrase@123"
key_id: "newkeyid123"
old_key: "OldPassPhrase@123"
tags:
- rekey_lkm
- name: Rekey in SEKM mode
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "ReKey"
controller_id: "RAID.Slot.1-1"
mode: "SEKM"
tags:
- rekey_sekm
- name: Remove controller key
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "RemoveControllerKey"
controller_id: "RAID.Slot.1-1"
tags:
- remove_controller_key
- name: Reset controller configuration
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "ResetConfig"
controller_id: "RAID.Slot.1-1"
tags:
- reset_config
- name: Enable controller encryption
idrac_redfish_storage_controller:
baseuri: "{{ baseuri }}"
username: "{{ username }}"
password: "{{ password }}"
ca_path: "/path/to/ca_cert.pem"
command: "EnableControllerEncryption"
controller_id: "RAID.Slot.1-1"
mode: "LKM"
key: "your_Key@123"
key_id: "your_Keyid@123"
tags:
- enable-encrypt
- name: Blink physical disk.
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: BlinkTarget
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- blink-target
- name: Blink virtual drive.
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: BlinkTarget
volume_id: "Disk.Virtual.0:RAID.Slot.1-1"
tags:
- blink-volume
- name: Unblink physical disk.
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: UnBlinkTarget
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- unblink-target
- name: Unblink virtual drive.
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: UnBlinkTarget
volume_id: "Disk.Virtual.0:RAID.Slot.1-1"
tags:
- unblink-drive
- name: Convert physical disk to RAID
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "ConvertToRAID"
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- convert-raid
- name: Convert physical disk to non-RAID
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "ConvertToNonRAID"
target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- convert-non-raid
- name: Change physical disk state to online.
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "ChangePDStateToOnline"
target: "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- pd-state-online
- name: Change physical disk state to offline.
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "ChangePDStateToOnline"
target: "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Slot.1-1"
tags:
- pd-state-offline
- name: Lock virtual drive
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
command: "LockVirtualDisk"
volume_id: "Disk.Virtual.0:RAID.SL.3-1"
tags:
- lock
- name: Online Capacity Expansion of a volume using target
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "{{ baseuri }}"
username: "{{ username }}"
password: "{{ password }}"
ca_path: "/path/to/ca_cert.pem"
command: "OnlineCapacityExpansion"
volume_id: "Disk.Virtual.0:RAID.Integrated.1-1"
target:
- "Disk.Bay.2:Enclosure.Internal.0-0:RAID.Integrated.1-1"
tags:
- oce_target
- name: Online Capacity Expansion of a volume using size
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "{{ baseuri }}"
username: "{{ username }}"
password: "{{ password }}"
ca_path: "/path/to/ca_cert.pem"
command: "OnlineCapacityExpansion"
volume_id: "Disk.Virtual.0:RAID.Integrated.1-1"
size: 362785
tags:
- oce_size
- name: Set controller attributes.
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
controller_id: "RAID.Slot.1-1"
attributes:
ControllerMode: "HBA"
apply_time: "OnReset"
tags:
- controller-attribute
- name: Configure controller attributes at Maintenance window
dellemc.openmanage.idrac_redfish_storage_controller:
baseuri: "192.168.0.1:443"
username: "user_name"
password: "user_password"
ca_path: "/path/to/ca_cert.pem"
controller_id: "RAID.Slot.1-1"
attributes:
CheckConsistencyMode: Normal
CopybackMode: "Off"
LoadBalanceMode: Disabled
apply_time: AtMaintenanceWindowStart
maintenance_window:
start_time: "2022-09-30T05:15:40-05:00"
duration: 1200
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key |
Description |
---|---|
Details of a http error. Returned: on http error Sample: |
|
Overall status of the storage controller configuration operation. Returned: always Sample: |
|
status of the submitted job. Returned: always Sample: |
|
ID and URI resource of the job created. Returned: success Sample: |