netapp_eseries.santricity.na_santricity_nvme_interface module – NetApp E-Series manage NVMe interface configuration
Note
This module is part of the netapp_eseries.santricity collection (version 1.4.0).
You might already have this collection installed if you are using the ansible
package.
It is not included in ansible-core
.
To check whether it is installed, run ansible-galaxy collection list
.
To install it, use: ansible-galaxy collection install netapp_eseries.santricity
.
To use it in a playbook, specify: netapp_eseries.santricity.na_santricity_nvme_interface
.
Synopsis
Configure settings of an E-Series NVMe interface
Parameters
Parameter |
Comments |
---|---|
The IPv4 address to assign to the NVMe interface |
|
The password to authenticate with the SANtricity Web Services Proxy or Embedded Web Services API. |
|
The url to the SANtricity Web Services Proxy or Embedded Web Services API. |
|
The username to authenticate with the SANtricity Web Services Proxy or Embedded Web Services API. |
|
This option specifies the which NVMe controller channel to configure. The list of choices is not necessarily comprehensive. It depends on the number of ports that are available in the system. The numerical value represents the number of the channel (typically from left to right on the HIC), beginning with a value of 1. |
|
The configuration method type to use for this interface. Only applicable when configuring RoCE dhcp is mutually exclusive with address, subnet_mask, and gateway. Choices:
|
|
The controller that owns the port you want to configure. Controller names are presented alphabetically, with the first controller as A and the second as B. Choices:
|
|
The IPv4 gateway address to utilize for the interface. Only applicable when configuring RoCE Mutually exclusive with config_method=dhcp |
|
The maximum transmission units (MTU), in bytes. Only applicable when configuring RoCE This allows you to configure a larger value for the MTU, in order to enable jumbo frames (any value > 1500). Generally, it is necessary to have your host, switches, and other components not only support jumbo frames, but also have it configured properly. Therefore, unless you know what you’re doing, it’s best to leave this at the default. Default: |
|
This is the ethernet port speed measured in Gb/s. Value must be a supported speed or auto for automatically negotiating the speed with the port. Only applicable when configuring RoCE The configured ethernet port speed should match the speed capability of the SFP on the selected port. Default: |
|
The ID of the array to manage. This value must be unique for each array. Default: |
|
Whether or not the specified RoCE interface should be enabled. Only applicable when configuring RoCE Choices:
|
|
The subnet mask to utilize for the interface. Only applicable when configuring RoCE Mutually exclusive with config_method=dhcp |
|
Should https certificates be validated? Choices:
|
Notes
Note
The E-Series Ansible modules require either an instance of the Web Services Proxy (WSP), to be available to manage the storage-system, or an E-Series storage-system that supports the Embedded Web Services API.
Embedded Web Services is currently available on the E2800, E5700, EF570, and newer hardware models.
ERROR while parsing: While parsing “M(netapp_e_storage_system)” at index 1: Module name “netapp_e_storage_system” is not a FQCN may be utilized for configuring the systems managed by a WSP instance.
Examples
Return Values
Common return values are documented here, the following are the fields unique to this module:
Key |
Description |
---|---|
Success message Returned: on success Sample: |