Synopsis

  • This module allows the users to configure the settings of the physical disk, virtual disk, and storage controller.

Requirements

The below requirements are needed on the host that executes this module.

  • python >= 3.9.6

Parameters

Parameter

Comments

apply_time

string

Apply time of the attributes.

This is applicable only to attributes.

Immediate Allows the user to immediately reboot the host and apply the changes. job_wait is applicable.

OnReset Allows the user to apply the changes on the next reboot of the host server.

AtMaintenanceWindowStart Allows the user to apply at the start of a maintenance window as specified in maintenance_window.

InMaintenanceWindowOnReset Allows to apply after a manual reset but within the maintenance window as specified in maintenance_window.

Choices:

  • "Immediate" ← (default)

  • "OnReset"

  • "AtMaintenanceWindowStart"

  • "InMaintenanceWindowOnReset"

attributes

dictionary

Dictionary of controller attributes and value pair.

This feature is only supported for iDRAC9 with firmware version 6.00.00.00 and above

controller_id is required for this operation.

apply_time and maintenance_window is applicable for attributes.

attributes is mutually exclusive with command.

Use https://I(idrac_ip/redfish/v1/Schemas/DellOemStorageController.json) to view the attributes.

baseuri

string / required

IP address of the target out-of-band controller. For example- <ipaddress>:<port>.

ca_path

path

added in dellemc.openmanage 5.0.0

The Privacy Enhanced Mail (PEM) file that contains a CA certificate to be used for the validation.

command

string

These actions may require a system reset, depending on the capabilities of the controller.

ResetConfig - Deletes all the virtual disks and unassigns all hot spares on physical disks. controller_id is required for this operation.

AssignSpare - Assigns a physical disk as a dedicated or global hot spare for a virtual disk. target is required for this operation.

SetControllerKey - Sets the key on controllers, which is used to encrypt the drives in Local Key Management(LKM). controller_id, key, and key_id are required for this operation.

RemoveControllerKey - Deletes the encryption key on the controller. controller_id is required for this operation.

ReKey - Resets the key on the controller and it always reports as changes found when check mode is enabled. controller_id, old_key, key_id, and key is required for this operation.

UnassignSpare - To unassign the Global or Dedicated hot spare. target is required for this operation.

EnableControllerEncryption - To enable Local Key Management (LKM) or Secure Enterprise Key Manager (SEKM) on controllers that support encryption of the drives. controller_id, key, and key_id are required for this operation.

BlinkTarget - Blinks the target virtual drive or physical disk and it always reports as changes found when check mode is enabled. target or volume_id is required for this operation.

UnBlinkTarget - Unblink the target virtual drive or physical disk and and it always reports as changes found when check mode is enabled. target or volume_id is required for this operation.

ConvertToRAID - Converts the disk form non-Raid to Raid. target is required for this operation.

ConvertToNonRAID - Converts the disk form Raid to non-Raid. target is required for this operation.

ChangePDStateToOnline - To set the disk status to online. target is required for this operation.

ChangePDStateToOffline - To set the disk status to offline. target is required for this operation.

LockVirtualDisk - To encrypt the virtual disk. volume_id is required for this operation.

OnlineCapacityExpansion - To expand the size of virtual disk. volume_id, and target or size is required for this operation.

SecureErase - To delete all the data on the physical disk securely. This option is available for Self-Encrypting Drives (SED), Instant Scramble Erase (ISE) drives, and PCIe SSD devices (drives and cards). The drives must be in a ready state. controller_id and target are required for this operation, target must be a single physical disk ID. If a secure erase needs a reboot, the job will get scheduled and waits for no of seconds specfied in job_wait_time, to reduce the wait time either give job_wait_time minimum or make job_wait as false.

Choices:

  • "ResetConfig"

  • "AssignSpare"

  • "SetControllerKey"

  • "RemoveControllerKey"

  • "ReKey"

  • "UnassignSpare"

  • "EnableControllerEncryption"

  • "BlinkTarget"

  • "UnBlinkTarget"

  • "ConvertToRAID"

  • "ConvertToNonRAID"

  • "ChangePDStateToOnline"

  • "ChangePDStateToOffline"

  • "LockVirtualDisk"

  • "OnlineCapacityExpansion"

  • "SecureErase"

controller_id

string

Fully Qualified Device Descriptor (FQDD) of the storage controller. For example-‘RAID.Slot.1-1’.

This option is mandatory when command is ResetConfig, SetControllerKey, RemoveControllerKey, ReKey, or EnableControllerEncryption.

This option is mandatory for attributes.

job_wait

boolean

Provides the option if the module has to wait for the job to be completed.

This is applicable for attributes when apply_time is Immediate and when command is SecureErase.

Choices:

  • false ← (default)

  • true

job_wait_timeout

integer

The maximum wait time of job completion in seconds before the job tracking is stopped.

This option is applicable when job_wait is true.

Note: When command is SecureErase, If a secure erase needs a reboot, the job will get scheduled and waits for no of seconds specfied in job_wait_time, to reduce the wait time either give job_wait_time a lesser value or make job_wait as false.

Default: 120

key

string

A new security key passphrase that the encryption-capable controller uses to create the encryption key. The controller uses the encryption key to lock or unlock access to the Self-Encrypting Drive (SED). Only one encryption key can be created for each controller.

This is mandatory when command is SetControllerKey, ReKey, or EnableControllerEncryption and when mode is LKM.

The length of the key can be a maximum of 32 characters in length, where the expanded form of the special character is counted as a single character.

The key must contain at least one character from each of the character classes: uppercase, lowercase, number, and special character.

key_id

string

This is a user supplied text label associated with the passphrase.

This is mandatory when command is SetControllerKey, ReKey, or EnableControllerEncryption and when mode is LKM.

The length of key_id can be a maximum of 32 characters in length and should not have any spaces.

maintenance_window

dictionary

Option to schedule the maintenance window.

This is required when apply_time is AtMaintenanceWindowStart or InMaintenanceWindowOnReset.

duration

integer

The duration in seconds for the maintenance window.

Default: 900

start_time

string / required

The start time for the maintenance window to be scheduled.

The format is YYYY-MM-DDThh:mm:ss<offset>

<offset> is the time offset from UTC that the current timezone set in iDRAC in the format: +05:30 for IST.

mode

string

Encryption mode of the encryption capable controller.

This option is applicable only when command is ReKey or EnableControllerEncryption.

SEKM requires secure enterprise key manager license on the iDRAC.

LKM to choose mode as local key mode.

Choices:

  • "LKM" ← (default)

  • "SEKM"

old_key

string

Security key passphrase used by the encryption-capable controller.

This option is mandatory when command is ReKey and mode is LKM.

password

string

Password of the target out-of-band controller.

If the password is not provided, then the environment variable IDRAC_PASSWORD is used.

Example: export IDRAC_PASSWORD=password

size

integer

Capacity of the virtual disk to be expanded in MB.

Check mode and Idempotency is not supported for size.

Minimum Online Capacity Expansion size must be greater than 100 MB of the current size.

When command is OnlineCapacityExpansion, then size is mutually exclusive with target.

target

aliases: drive_id

list / elements=string

Fully Qualified Device Descriptor (FQDD) of the target physical drive.

This is mandatory when command is AssignSpare, UnassisgnSpare, ChangePDStateToOnline, ChangePDStateToOffline, ConvertToRAID, or ConvertToNonRAID.

If volume_id is not specified or empty, this physical drive will be assigned as a global hot spare when command is AssignSpare.

When command is OnlineCapacityExpansion, then target is mutually exclusive with size.

Notes: Global or Dedicated hot spare can be assigned only once for a physical disk, Re-assign cannot be done when command is AssignSpare.

timeout

integer

added in dellemc.openmanage 5.0.0

The socket level timeout in seconds.

Default: 30

username

string

Username of the target out-of-band controller.

If the username is not provided, then the environment variable IDRAC_USERNAME is used.

Example: export IDRAC_USERNAME=username

validate_certs

boolean

added in dellemc.openmanage 5.0.0

If false, the SSL certificates will not be validated.

Configure false only on personally controlled sites where self-signed certificates are used.

Prior to collection version 5.0.0, the validate_certs is false by default.

Choices:

  • false

  • true ← (default)

volume_id

list / elements=string

Fully Qualified Device Descriptor (FQDD) of the volume.

Applicable if command is AssignSpare, BlinkTarget, UnBlinkTarget or LockVirtualDisk.

volume_id or target is required when the command is BlinkTarget or UnBlinkTarget, if both are specified target is considered.

To know the number of volumes to which a hot spare can be assigned, refer iDRAC Redfish API documentation.

x_auth_token

string

added in dellemc.openmanage 9.3.0

Authentication token.

If the x_auth_token is not provided, then the environment variable IDRAC_X_AUTH_TOKEN is used.

Example: export IDRAC_X_AUTH_TOKEN=x_auth_token

Notes

Note

  • Run this module from a system that has direct access to Dell iDRAC.

  • This module is supported on iDRAC9.

  • This module supports IPv4 and IPv6 addresses.

  • This module always reports as changes found when command is ReKey, BlinkTarget, and UnBlinkTarget.

  • This module supports check_mode.

Examples

---
- name: Assign dedicated hot spare
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    volume_id:
      - "Disk.Virtual.0:RAID.Slot.1-1"
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - assign_dedicated_hot_spare

- name: Assign global hot spare
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - assign_global_hot_spare

- name: Unassign hot spare
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
    command: UnassignSpare
  tags:
    - un-assign-hot-spare

- name: Set controller encryption key
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "SetControllerKey"
    controller_id: "RAID.Slot.1-1"
    key: "PassPhrase@123"
    key_id: "mykeyid123"
  tags:
    - set_controller_key

- name: Rekey in LKM mode
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "ReKey"
    controller_id: "RAID.Slot.1-1"
    key: "NewPassPhrase@123"
    key_id: "newkeyid123"
    old_key: "OldPassPhrase@123"
  tags:
    - rekey_lkm

- name: Rekey in SEKM mode
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "ReKey"
    controller_id: "RAID.Slot.1-1"
    mode: "SEKM"
  tags:
    - rekey_sekm

- name: Remove controller key
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "RemoveControllerKey"
    controller_id: "RAID.Slot.1-1"
  tags:
    - remove_controller_key

- name: Reset controller configuration
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "ResetConfig"
    controller_id: "RAID.Slot.1-1"
  tags:
    - reset_config

- name: Enable controller encryption
  idrac_redfish_storage_controller:
    baseuri: "{{ baseuri }}"
    username: "{{ username }}"
    password: "{{ password }}"
    ca_path: "/path/to/ca_cert.pem"
    command: "EnableControllerEncryption"
    controller_id: "RAID.Slot.1-1"
    mode: "LKM"
    key: "your_Key@123"
    key_id: "your_Keyid@123"
  tags:
    - enable-encrypt

- name: Blink physical disk.
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: BlinkTarget
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - blink-target

- name: Blink virtual drive.
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: BlinkTarget
    volume_id: "Disk.Virtual.0:RAID.Slot.1-1"
  tags:
    - blink-volume

- name: Unblink physical disk.
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: UnBlinkTarget
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - unblink-target

- name: Unblink virtual drive.
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: UnBlinkTarget
    volume_id: "Disk.Virtual.0:RAID.Slot.1-1"
  tags:
    - unblink-drive

- name: Convert physical disk to RAID
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "ConvertToRAID"
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - convert-raid

- name: Convert physical disk to non-RAID
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "ConvertToNonRAID"
    target: "Disk.Bay.0:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - convert-non-raid

- name: Change physical disk state to online.
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "ChangePDStateToOnline"
    target: "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - pd-state-online

- name: Change physical disk state to offline.
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "ChangePDStateToOnline"
    target: "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Slot.1-1"
  tags:
    - pd-state-offline

- name: Lock virtual drive
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    command: "LockVirtualDisk"
    volume_id: "Disk.Virtual.0:RAID.SL.3-1"
  tags:
    - lock

- name: Online Capacity Expansion of a volume using target
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "{{ baseuri }}"
    username: "{{ username }}"
    password: "{{ password }}"
    ca_path: "/path/to/ca_cert.pem"
    command: "OnlineCapacityExpansion"
    volume_id: "Disk.Virtual.0:RAID.Integrated.1-1"
    target:
      - "Disk.Bay.2:Enclosure.Internal.0-0:RAID.Integrated.1-1"
  tags:
    - oce_target

- name: Online Capacity Expansion of a volume using size
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "{{ baseuri }}"
    username: "{{ username }}"
    password: "{{ password }}"
    ca_path: "/path/to/ca_cert.pem"
    command: "OnlineCapacityExpansion"
    volume_id: "Disk.Virtual.0:RAID.Integrated.1-1"
    size: 362785
  tags:
    - oce_size

- name: Set controller attributes.
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    controller_id: "RAID.Slot.1-1"
    attributes:
      ControllerMode: "HBA"
    apply_time: "OnReset"
  tags:
    - controller-attribute

- name: Configure controller attributes at Maintenance window
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    controller_id: "RAID.Slot.1-1"
    attributes:
      CheckConsistencyMode: Normal
      CopybackMode: "Off"
      LoadBalanceMode: Disabled
    apply_time: AtMaintenanceWindowStart
    maintenance_window:
      start_time: "2022-09-30T05:15:40-05:00"
      duration: 1200

- name: Perform Secure Erase operation on SED drive
  dellemc.openmanage.idrac_redfish_storage_controller:
    baseuri: "192.168.0.1:443"
    username: "user_name"
    password: "user_password"
    ca_path: "/path/to/ca_cert.pem"
    controller_id: "RAID.Slot.1-1"
    command: "SecureErase"
    target: "Disk.Bay.1:Enclosure.Internal.0-1:RAID.Slot.1-1"

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key

Description

error_info

dictionary

Details of a http error.

Returned: on http error

Sample: {"error": {"@Message.ExtendedInfo": [{"Message": "Unable to run the method because the requested HTTP method is not allowed.", "MessageArgs": [], "MessageArgs@odata.count": 0, "MessageId": "iDRAC.1.6.SYS402", "RelatedProperties": [], "RelatedProperties@odata.count": 0, "Resolution": "Enter a valid HTTP method and retry the operation. For information about valid methods, see the Redfish Users Guide available on the support site.", "Severity": "Informational"}], "code": "Base.1.0.GeneralError", "message": "A general error has occurred. See ExtendedInfo for more information"}}

msg

string

Overall status of the storage controller configuration operation.

Returned: always

Sample: "Successfully submitted the job that performs the AssignSpare operation"

status

dictionary

status of the submitted job.

Returned: always

Sample: {"ActualRunningStartTime": "2022-02-09T04:42:41", "ActualRunningStopTime": "2022-02-09T04:44:00", "CompletionTime": "2022-02-09T04:44:00", "Description": "Job Instance", "EndTime": "TIME_NA", "Id": "JID_444033604418", "JobState": "Completed", "JobType": "RealTimeNoRebootConfiguration", "Message": "Job completed successfully.", "MessageArgs": [], "MessageId": "PR19", "Name": "Configure: RAID.Integrated.1-1", "PercentComplete": 100, "StartTime": "2022-02-09T04:42:40", "TargetSettingsURI": null}

task

dictionary

ID and URI resource of the job created.

Returned: success

Sample: {"id": "JID_XXXXXXXXXXXXX", "uri": "/redfish/v1/Managers/iDRAC.Embedded.1/Jobs/JID_XXXXXXXXXXXXX"}

Authors

  • Jagadeesh N V (@jagadeeshnv)

  • Felix Stephen (@felixs88)

  • Husniya Hameed (@husniya_hameed)

  • Abhishek Sinha (@ABHISHEK-SINHA10)