dellemc.openmanage.ome_chassis_slots module – Rename sled slots on OpenManage Enterprise Modular

Note

This module is part of the dellemc.openmanage collection (version 9.9.0).

You might already have this collection installed if you are using the ansible package. It is not included in ansible-core. To check whether it is installed, run ansible-galaxy collection list.

To install it, use: ansible-galaxy collection install dellemc.openmanage. You need further requirements to be able to use this module, see Requirements for details.

To use it in a playbook, specify: dellemc.openmanage.ome_chassis_slots.

New in dellemc.openmanage 3.6.0

Synopsis

  • This module allows to rename sled slots on OpenManage Enterprise Modular either using device id or device service tag or using chassis service tag and slot number.

Requirements

The below requirements are needed on the host that executes this module.

  • python >= 3.9.6

Parameters

Parameter

Comments

ca_path

path

added in dellemc.openmanage 5.0.0

The Privacy Enhanced Mail (PEM) file that contains a CA certificate to be used for the validation.

device_options

list / elements=dictionary

The ID or service tag of the sled in the slot and the new name for the slot.

device_options is mutually exclusive with slot_options.

device_id

integer

Device ID of the sled in the slot.

This is mutually exclusive with device_service_tag.

device_service_tag

string

Service tag of the sled in the slot.

This is mutually exclusive with device_id.

slot_name

string / required

Provide name for the slot.

hostname

string / required

OpenManage Enterprise Modular IP address or hostname.

password

string

OpenManage Enterprise Modular password.

If the password is not provided, then the environment variable OME_PASSWORD is used.

Example: export OME_PASSWORD=password

port

integer

OpenManage Enterprise Modular HTTPS port.

Default: 443

slot_options

list / elements=dictionary

The service tag of the chassis, slot number of the slot to be renamed, and the new name for the slot.

slot_options is mutually exclusive with device_options.

chassis_service_tag

string / required

Service tag of the chassis.

slots

list / elements=dictionary / required

The slot number and the new name for the slot.

slot_name

string / required

Provide name for the slot.

slot_number

integer / required

The slot number of the slot to be renamed.

timeout

integer

added in dellemc.openmanage 5.0.0

The socket level timeout in seconds.

Default: 30

username

string

OpenManage Enterprise Modular username.

If the username is not provided, then the environment variable OME_USERNAME is used.

Example: export OME_USERNAME=username

validate_certs

boolean

added in dellemc.openmanage 5.0.0

If false, the SSL certificates will not be validated.

Configure false only on personally controlled sites where self-signed certificates are used.

Prior to collection version 5.0.0, the validate_certs is false by default.

Choices:

  • false

  • true ← (default)

x_auth_token

string

added in dellemc.openmanage 9.3.0

Authentication token.

If the x_auth_token is not provided, then the environment variable OME_X_AUTH_TOKEN is used.

Example: export OME_X_AUTH_TOKEN=x_auth_token

Notes

Note

  • This module initiates the refresh inventory task. It may take a minute for new names to be reflected. If the task exceeds 300 seconds to refresh, the task times out.

  • Run this module from a system that has direct access to Dell OpenManage Enterprise Modular.

  • This module supports check_mode.

Examples

---
- name: Rename the slots in multiple chassis using slot number and chassis service tag
  dellemc.openmanage.ome_chassis_slots:
    hostname: "192.168.0.1"
    username: "username"
    password: "password"
    ca_path: "/path/to/ca_cert.pem"
    slot_options:
      - chassis_service_tag: ABC1234
        slots:
          - slot_number: 1
            slot_name: sled_name_1
          - slot_number: 2
            slot_name: sled_name_2
      - chassis_service_tag: ABC1235
        slots:
          - slot_number: 1
            slot_name: sled_name_1
          - slot_number: 2
            slot_name: sled_name_2

- name: Rename single slot name of the sled using sled ID
  dellemc.openmanage.ome_chassis_slots:
    hostname: "192.168.0.1"
    username: "username"
    password: "password"
    ca_path: "/path/to/ca_cert.pem"
    device_options:
      - device_id: 10054
        slot_name: slot_device_name_1

- name: Rename single slot name of the sled using sled service tag
  dellemc.openmanage.ome_chassis_slots:
    hostname: "192.168.0.1"
    username: "username"
    password: "password"
    ca_path: "/path/to/ca_cert.pem"
    device_options:
      - device_service_tag: ABC1234
        slot_name: service_tag_slot

- name: Rename multiple slot names of the devices
  dellemc.openmanage.ome_chassis_slots:
    hostname: "192.168.0.1"
    username: "username"
    password: "password"
    ca_path: "/path/to/ca_cert.pem"
    device_options:
      - device_id: 10054
        slot_name: sled_name_1
      - device_service_tag: ABC1234
        slot_name: sled_name_2
      - device_id: 10055
        slot_name: sled_name_3
      - device_service_tag: PQR1234
        slot_name: sled_name_4

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key

Description

error_info

dictionary

Details of the HTTP Error.

Returned: on HTTP error

Sample: {"error": {"@Message.ExtendedInfo": [{"Message": "Unable to complete the operation because an invalid value is entered for the property Invalid json type: STRING for Edm.Int64 property: Id .", "MessageArgs": ["Invalid json type: STRING for Edm.Int64 property: Id"], "MessageId": "CGEN1014", "RelatedProperties": [], "Resolution": "Enter a valid value for the property and retry the operation. For more information about valid values, see the OpenManage Enterprise-Modular User's Guide available on the support site.", "Severity": "Critical"}], "code": "Base.1.0.GeneralError", "message": "A general error has occurred. See ExtendedInfo for more information."}}

msg

string

Overall status of the slot rename operation.

Returned: always

Sample: "Successfully renamed the slot(s)."

rename_failed_slots

list / elements=dictionary

Information of the valid slots that are not renamed.

JobStatus is shown if rename job fails.

NOTE Only slots which were not renamed are listed.

Returned: if at least one slot renaming fails

Sample: [{"ChassisId": "12345", "ChassisName": "MX-ABCD123", "ChassisServiceTag": "ABCD123", "DeviceType": "4000", "JobId": 1234, "JobStatus": "Aborted", "SlotId": "10061", "SlotName": "c2", "SlotNumber": "1", "SlotType": "4000"}, {"ChassisId": "10053", "ChassisName": "MX-PQRS123", "ChassisServiceTag": "PQRS123", "DeviceType": "1000", "JobId": 0, "JobStatus": "HTTP Error 400: Bad Request", "SlotId": "10069", "SlotName": "b2", "SlotNumber": "3", "SlotType": "2000"}]

slot_info

list / elements=dictionary

Information of the slots that are renamed successfully.

The DeviceServiceTag and DeviceId options are available only if device_options is used.

NOTE Only the slots which were renamed are listed.

Returned: if at least one slot renamed

Sample: [{"ChassisId": 10053, "ChassisServiceTag": "ABCD123", "DeviceName": "", "DeviceType": 1000, "JobId": 15746, "SlotId": "10072", "SlotName": "slot_op2", "SlotNumber": "6", "SlotType": 2000}, {"ChassisId": 10053, "ChassisName": "MX-ABCD123", "ChassisServiceTag": "ABCD123", "DeviceType": "3000", "JobId": 15747, "SlotId": "10070", "SlotName": "slot_op2", "SlotNumber": "4", "SlotType": "2000"}, {"ChassisId": "10053", "ChassisName": "MX-PQRS123", "ChassisServiceTag": "PQRS123", "DeviceId": "10054", "DeviceServiceTag": "XYZ5678", "DeviceType": "1000", "JobId": 15761, "SlotId": "10067", "SlotName": "a1", "SlotNumber": "1", "SlotType": "2000"}]

Authors

  • Jagadeesh N V(@jagadeeshnv)